DEKORON UNITHERM · SUPPLIED BY PMA

Keep the heat. Protect the journey.

Insulated transport for steam, gas and liquid, with a continuous protective jacket around the line.

Pre-insulated tubing construction displayed in a technical office

PRE-INSULATED TUBING

Less heat lost. A complete transport line.

Series 2200 combines process tubing, thermal insulation and a continuous extruded polymer jacket. It reduces heat loss during transport without an integral electric heater. Used in refinery and petrochemical applications, it connects steam supply manifolds to tracing systems and returns condensate towards the boiler.

Pre-insulated tubing bundle detail

Built around your duty.

Consider the fluid, temperature, insulation and outer jacket as a single transport assembly.

Steam distribution

Connect steam supply manifolds to pipe and vessel tracing. Specify the supply conditions and route alongside the process tubing.

Condensate return

Insulation helps reduce heat loss on the return journey. Review connections, drainage and the installation environment.

Continuous outer jacket

The extruded polymer jacket protects the insulation against moisture. Correct end seals and terminations remain essential.

No integral heater

Pre-insulation reduces heat loss; it does not add heat. Review prolonged cold shutdowns separately where freezing is possible.

TECHNICAL INFORMATION

The detail behind the line.

Published range information and the inputs needed to specify your assembly.

Pre-insulated tubing · specification guide
ParameterRange information / requirement
Product familySeries 2200 pre-insulated transport tubing
Transport mediaSteam, gas or liquid, subject to material compatibility
Tube sizes in the range¼, ⅜, ½ and ¾ inch
Common tube materials316/316L stainless steel, copper and PFA; construction dependent
Manufacturer’s Series 2200 example204°C saturated steam at 26°C ambient; jacket surface at or below 60°C
Outer protectionContinuous extruded polymer jacket
Heating arrangementNo integral electric heater
Specify with PMAPressure, temperature, tubing, route, jacket environment and end connections

Surface temperatures depend on the product construction and operating conditions. Other specialist range ratings require separate confirmation; insulation alone does not guarantee freeze protection.

Manufacturer product information

APPLICATION STARTING POINTS

Designed around the process.

Tell us what the line needs to do, then review the complete construction with PMA.

Steam supply

Distribute steam from supply manifolds to tracing systems in process facilities.

Condensate systems

Return condensate with an insulated line considered around heat loss, routing and connections.

Gas & liquid transport

Match tube material, pressure and temperature to the medium and environment.

PMA colleagues reviewing an engineering application

PRODUCT DOCUMENTS

Take the detail with you.

The manufacturer’s two-page June 2026 line card provides an overview of Dekoron Unitherm tubing families. Ask PMA for the datasheet, installation instructions and certification relevant to your selected construction.

Download range brochure PDFRequest product-specific documents

USEFUL TO KNOW

Your questions, answered.

Will pre-insulated tubing stop a line freezing?

Insulation slows heat loss but does not generate heat. A prolonged cold shutdown can still cause freezing. Discuss active heating where the process requires it.

Where is Series 2200 commonly used?

The manufacturer describes refinery and petrochemical steam distribution and condensate return applications. Suitability depends on the exact fluid, conditions and supplied construction.

What should I send for a quotation?

Include the medium, pressure, normal and maximum temperatures, ambient conditions, tube size and material, length, routing, supports and required end connections.

Let’s talk about
your application.

Talk to PMA about pre-insulated tubing. Share the fluid, temperature duty and installation details so we can review the complete tubing assembly.

  • Advice for your application. Review the tube material, heating arrangement, insulation and jacket around your process.
  • Practical service support. Ask about product documentation, termination accessories and installation requirements.
  • Clear next steps. Ask a technical question or request a callback, with your site and measurements in mind.
  • An enquiry, not a mailing list. Your details are used to respond to you. You won’t be added to a marketing database.

Prefer to speak with us?

Call 01484 843 708

You can also email sales@pma.uk.com.

Tell us how we can help

Share your requirements below. All fields are required.

Privacy *

The details you share are used so that our team can respond to your enquiry. Please refer to our privacy policy for how we protect your data. Spam protection is provided by Cloudflare Turnstile; its Privacy Policy and Turnstile Privacy Addendum apply.

Loading spam protection…

Thank you for choosing PMA.

Your details are used to respond to you, and you won’t be added to a marketing database. Read our privacy policy.